Minimizing the Interaction of Phospholipids with LC Hardware
Applications | 2023 | Agilent TechnologiesInstrumentation
HPLC, LC/MS, LC/SQ
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies
Key wordssst, lpa, pip, peek, bio, infinitylab, phospholipids, column, phosphatidylinositol, msd, stainless, steel, lined, adsorption, thermostat, pips, ammonium, phosphorylated, phosphatidic, interaction, counts, retention, response, main, agilent, multicolumn, performance, nonspecific, phosphate, min, electrospray, biocompatible, using, challenging, low, species, time, abundance, detection, acid, class, flow, liquid, detected, various, koen, fatty, system, recovery, biochemicals
Similar PDF
Determining mRNA Capping with HILIC-MS on a Low-Adsorption Flow Path
2024|Agilent Technologies|Applications
Application Note Biopharma/Pharma Determining mRNA Capping with HILIC-MS on a Low-Adsorption Flow Path Limiting interfering interactions with metal using the Agilent 1290 Infinity II Bio LC System Authors Gerd Vanhoenacker, Kris Morreel, Stefanie Jonckheere, Pat Sandra, and Koen Sandra RIC…
Key words
rnase, rnasemrna, mrnastainless, stainlesssteel, steelprobe, probehybridization, hybridizationrna, rnapath, pathnucleic, nucleiccleavage, cleavagesurfaces, surfacescapping, cappinghilic, hilicmetal, metalflow
Comparability Studies for the Analysis of Nucleotides on Four Different LC Systems
2021|Agilent Technologies|Applications
Application Note Biopharma Comparability Studies for the Analysis of Nucleotides on Four Different LC Systems Bio versus stainless steel systems ×101 2.8 Adenosine 2.6 2.4 Response (mAU) 2.2 AMP 2.0 1.8 ADP ATP 1.6 1.4 1.2 1.0 0.8 0.6 0.4…
Key words
adenosine, adenosinephosphorylated, phosphorylatedadp, adpamp, ampatp, atploss, lossstainless, stainlessnucleotides, nucleotidesbio, biosteel, steeliron, ironinfinity, infinitysystems, systemsexchanger, exchangerarea
HPLC-DAD Analysis of Nucleotides Using a Fully Inert Flowpath - Agilent 1260 Infinity II Bio-Inert LC System and a PEEK-lined Agilent InfinityLab Poroshell 120 HILIC-Z Column
2019|Agilent Technologies|Applications
Application Note Pharma & Biopharma HPLC-DAD Analysis of Nucleotides Using a Fully Inert Flowpath Agilent 1260 Infinity II Bio-Inert LC System and a PEEK-lined Agilent InfinityLab Poroshell 120 HILIC-Z Column Authors Koen Sandra, Jonathan Vandenbussche, Gerd Vanhoenacker, Ruben t’Kindt, and…
Key words
lined, linedpeek, peekinert, inertmau, maustainless, stainlessatp, atpsteel, steelamp, ampadp, adpresponse, responsecolumn, columnnucleotides, nucleotidesretention, retentionmin, minutp
Native SEC/MS Analysis of mAbs on an Entirely Biocompatible Flow Path
2023|Agilent Technologies|Applications
Application Note Biopharma/Pharma Native SEC/MS Analysis of mAbs on an Entirely Biocompatible Flow Path Using the Agilent 1290 Infinity II Bio LC System and Agilent AdvanceBio SEC 200 Å 1.9 µm PEEK-lined column in mAbs analysis Authors Abstract Liesa Verscheure,…
Key words
sec, secretention, retentionpeek, peekmin, mincolumn, columnnistmab, nistmabmau, maunative, nativesst, sstbio, biotime, timelined, linedresponse, responsedeconvoluted, deconvolutedtrastuzumab