Goog HPLC practice guide
Guides | 2021 | KNAUERInstrumentation
High-performance liquid chromatography (HPLC) is a cornerstone of modern analytical chemistry, enabling precise separation, identification and quantification of compounds in diverse fields such as pharmaceuticals, environmental monitoring and food analysis. Adhering to robust HPLC practices is essential to maintain data integrity, avoid system contamination and extend equipment lifetime.
This guide consolidates best practices covering mobile phase preparation, detection strategies, sample handling, laboratory safety and system operation. Its aim is to offer a clear, step-by-step reference that helps analysts optimize routine HPLC workflows and minimize instrument downtime.
Key recommendations include:
Implementing these best practices ensures stable baselines, prevents ghost peaks and pressure spikes, and maintains consistent retention times. Proper solvent handling and system equilibration safeguard columns and pump components from damage under extreme pH or non-miscible solvent conditions.
Observing these guidelines delivers:
Emerging directions include adoption of greener solvent systems, fully automated online filtration and degassing modules, AI-driven method development to optimize gradients and detector settings, and integration of orthogonal detection techniques for comprehensive sample profiling.
Consistent application of structured HPLC workflows—from solvent and buffer preparation through detector calibration to system shutdown—ensures reliable, high-quality separations and maximizes laboratory efficiency.
HPLC
IndustriesManufacturerKNAUER
Summary
Importance of the Topic
High-performance liquid chromatography (HPLC) is a cornerstone of modern analytical chemistry, enabling precise separation, identification and quantification of compounds in diverse fields such as pharmaceuticals, environmental monitoring and food analysis. Adhering to robust HPLC practices is essential to maintain data integrity, avoid system contamination and extend equipment lifetime.
Study Objectives and Overview
This guide consolidates best practices covering mobile phase preparation, detection strategies, sample handling, laboratory safety and system operation. Its aim is to offer a clear, step-by-step reference that helps analysts optimize routine HPLC workflows and minimize instrument downtime.
Methodology and Instrumentation
Key recommendations include:
- Solvent Quality and Preparation: Use HPLC- or MS-grade solvents, prepare fresh buffers with controlled pH, filter mobile phases through ≥0.45 µm membranes and apply degassing methods (helium sparging, sonication, vacuum or online modules).
- Detection Considerations: Match analyte chromophores to detector wavelengths and select solvents with UV cutoff below analyte absorption to maintain baseline stability.
- Sample Preparation: Employ techniques such as filtration, centrifugation, solid-phase extraction and solubility screening to remove matrix interferences and protect column integrity.
- Laboratory Safety: Follow EN norms for eye and hand protection, consult MSDS for hazard assessment and select gloves based on permeation data.
- System Operation: Utilize structured start-up and shutdown checklists to ensure proper tubing installation, pump priming, column equilibration and post-run flushing.
Used Instrumentation
- KNAUER AZURA P 6.1L LPG and P 6.1L HPG pumps with integrated online degassers
- UV/Vis and diode array detectors with specified warm-up protocols
- Refractive index detectors requiring thermal stabilization
- Autosampler modules with programmable wash and needle-clearing routines
Main Results and Discussion
Implementing these best practices ensures stable baselines, prevents ghost peaks and pressure spikes, and maintains consistent retention times. Proper solvent handling and system equilibration safeguard columns and pump components from damage under extreme pH or non-miscible solvent conditions.
Benefits and Practical Applications
Observing these guidelines delivers:
- Enhanced reproducibility and analytical sensitivity
- Longer column and pump component lifetimes
- Reduced risk of baseline disturbances and system failures
- Streamlined routine maintenance and troubleshooting
Future Trends and Potential Applications
Emerging directions include adoption of greener solvent systems, fully automated online filtration and degassing modules, AI-driven method development to optimize gradients and detector settings, and integration of orthogonal detection techniques for comprehensive sample profiling.
Conclusion
Consistent application of structured HPLC workflows—from solvent and buffer preparation through detector calibration to system shutdown—ensures reliable, high-quality separations and maximizes laboratory efficiency.
References
- KNAUER Good LC Practices FAQ
- KNAUER LC Columns Care Guidelines
- Eluting Strength Influence in HPLC
- Column Care and Regeneration Protocols
- HILIC Column Maintenance Guide
- Silica Phase Column Care Manual
- EuroSpher and Chiral Column Care Recommendations
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Best Practices for Using an Agilent LC System - Technical Note
2022|Agilent Technologies|Technical notes
Best Practices for Using an Agilent LC System Technical Note This technical note describes best practices for using an Agilent LC system. Housekeeping 2 Daily / Weekly Tasks 5 Power Up / Shut Down the System Recommendations for Degassers Recommendations…
Key words
recommendations, recommendationspractices, practicesbest, bestnote, notetechnical, technicalpumps, pumpsseal, sealsamplers, samplerswash, washhousekeeping, housekeepingdamage, damagedegassers, degassersinline, inlinesolvent, solventmultiwash
Rittun User’s Guide for L-3320 Autosampler
2020|ECOM|Manuals
User’s Guide L-3320 Autosampler May. 2020 Rittun (Suzhou) Precision Measurement System Co., Ltd. Rittun Guaranty and Declaration Copyright © 2019 Rittun (Suzhou) Precision Measurement System Co., Ltd. All Rights Reserved. Trademark Information Rittun is a registered trademark of Rittun (Suzhou)…
Key words
rittun, rittunsyringe, syringequalification, qualificationinjection, injectionneedle, needletubing, tubingwash, washvalve, valveinitializing, initializingsystem, systemair, airinstrument, instrumentpower, powerhoming, homingsolvent
Eliminate your Application and Chromatography Challenges - Troubleshooting your Method, Application/Chromatography
2020|Agilent Technologies|Presentations
Eliminate your Application and Chromatography Challenges LC Application Scientist Session Information Contributed by USA HPLC Applications Scientist Team Speaker: Mike Woodman, LC AE Chicago area 1260 Infinity II Prime LC 1 May 29, 2020 DE.6300347222 800 bar 1260 Infinity II…
Key words
absorbance, absorbancesetting, settingdad, dadmau, mauchoose, choosetris, trismobile, mobileslit, slityour, yourbuffer, bufferreference, referencediluent, diluentphases, phasesdiode, diodebeam
Get Your LC Back Up and Running After the Shut Down
2020|Agilent Technologies|Guides
Get Your LC Back Up and Running After the Shut Down When you restart your LC systems after a long lab shutdown, you need to follow a systematic approach to avoid issues directly after a restart. Here is Agilent's guide…
Key words
your, yoursolvent, solventshutdown, shutdownafter, aftercables, cablesconnected, connecteddisconnect, disconnectconduct, conductdegasser, degassermaintenance, maintenancecheckup, checkuppreventivemaintenance, preventivemaintenanceqrg, qrgsystem, systemtube