Quantitative Analysis of High-Concentration Samples without Dilution - Introducing the UV-2700i Plus
Applications | 2025 | ShimadzuInstrumentation
UV-Vis spectrophotometry is essential for quantifying analytes in solution but is often limited by stray light at high absorbances, requiring sample dilution. The UV-2700i Plus extends the measurable range up to 8 Abs without dilution, improving efficiency and reducing preparation errors.
The study demonstrates the UV-2700i Plus’s ability to quantitatively analyze high-concentration samples and explores the spectrum-based quantitative analysis feature in LabSolutions UV-Vis software for optimized wavelength selection and calibration linearity.
The extended dynamic range eliminates dilution steps, reducing analysis time and potential errors. The spectrum-based approach is valuable for first-time method development, contaminated samples, and multi-component systems requiring customized wavelength selection.
The UV-2700i Plus UV-Vis spectrophotometer combined with LabSolutions spectrum-based quantitative analysis enables accurate, high-concentration sample measurement without dilution. Tailored wavelength selection preserves calibration linearity, enhancing reliability and efficiency in quantitative spectrophotometric assays.
UV–VIS spectrophotometry
IndustriesEnergy & Chemicals
ManufacturerShimadzu
Summary
Significance of the Topic
UV-Vis spectrophotometry is essential for quantifying analytes in solution but is often limited by stray light at high absorbances, requiring sample dilution. The UV-2700i Plus extends the measurable range up to 8 Abs without dilution, improving efficiency and reducing preparation errors.
Objectives and Study Overview
The study demonstrates the UV-2700i Plus’s ability to quantitatively analyze high-concentration samples and explores the spectrum-based quantitative analysis feature in LabSolutions UV-Vis software for optimized wavelength selection and calibration linearity.
Methodology and Instrumentation
- Instrument: UV-2700i Plus with double monochromator and Lo-Ray-Ligh low stray light gratings, high-absorbance measurement kit, 4 Abs neutral density filter.
- Software: LabSolutions UV-Vis with standard and spectrum-based quantitative analysis modes.
- Sample: Potassium permanganate solutions prepared at concentrations yielding absorbance from 1 to 10 Abs (65 to 650 mg/L).
- Standard method conditions: wavelength 525 nm, integration time 2 s, slit width 5 nm.
- Spectrum-based method: spectral scan 400–650 nm, data interval 0.1 nm, scanning speed medium, slit width 5 nm.
Main Results and Discussion
- Standard quantification achieved excellent linearity (r² = 0.99999) up to 8 Abs.
- Spectrum-based analysis at 525 nm maintained linearity to 8 Abs (r² = 0.99993) but deteriorated with higher absorbance (r² = 0.99498).
- By selecting a shoulder wavelength at 565 nm, linearity was restored for concentrations up to 10 Abs.
- The spectrum-based feature enables identification of optimal wavelengths, avoiding peak saturation and maximizing calibration accuracy.
Benefits and Practical Applications
The extended dynamic range eliminates dilution steps, reducing analysis time and potential errors. The spectrum-based approach is valuable for first-time method development, contaminated samples, and multi-component systems requiring customized wavelength selection.
Future Trends and Potential Applications
- Expansion to broader wavelength ranges and other high-absorbance analytes.
- Integration of AI-driven spectral analysis for automatic wavelength optimization.
- Multi-component quantitative analysis leveraging full spectral data.
- High-throughput screening in industrial and quality control environments.
Conclusion
The UV-2700i Plus UV-Vis spectrophotometer combined with LabSolutions spectrum-based quantitative analysis enables accurate, high-concentration sample measurement without dilution. Tailored wavelength selection preserves calibration linearity, enhancing reliability and efficiency in quantitative spectrophotometric assays.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
UV-2600i Plus, UV-2700i Plus UV-Vis Spectrophotometers
2025|Shimadzu|Brochures and specifications
C101-E184 UV-Vis Spectrophotometers UV-2600i Plus UV-2700i Plus Perfect for a Wide Variety of Applications By accommodating a wealth of accessories, the system can address any user’s applications and a variety of situations. Measures Slight Differences in Absorbance Scalability to near-infrared…
Key words
measurements, measurementsvis, vislabsolutions, labsolutionsfilm, filmtransmittance, transmittancereflectance, reflectanceautomatic, automaticholder, holdersphere, spheredata, dataintegrating, integratingmeasurement, measurementangle, angleultraviolet, ultravioletfilms
UV-VIS Spectrophotometer UV-2600i UV-2700i
2024|Shimadzu|Brochures and specifications
C101-E169A UV-VIS Spectrophotometer UV-2600i UV-2700i D on ’t Mis s Any Pie ce of th e Puzzle Single monochromator UV-2600i Double monochromator UV-2700i UV-i Selection UV-1900i UV-2600i/2700i UV-3600i Plus SolidSpec ™-3700i Perfect for a Wide Variety of Applications By accommodating…
Key words
measurements, measurementsvis, vislabsolutions, labsolutionsfilm, filmtransmittance, transmittancemeasurement, measurementholder, holderreflectance, reflectancedata, dataautomatic, automaticsphere, sphereintegrating, integratingultraviolet, ultravioletoperations, operationsmanagement
Using the Spectral Evaluation Function for Quantitative Analysis of Nucleotides and a Simultaneous Pass/Fail Judgment on Nucleotide Sample Purity
2025|Shimadzu|Applications
UV-Vis Spectrophotometer UV-1900i Plus Application News Using the Spectral Evaluation Function for Quantitative Analysis of Nucleotides and a Simultaneous Pass/Fail Judgment on Nucleotide Sample Purity Naoki Okamoto and Kazuki Sobue User Benefits Use the Spectral Evaluation Function to set…
Key words
judgment, judgmentquantitative, quantitativeevaluation, evaluationfail, failnucleic, nucleicfunction, functionwavelength, wavelengthspectral, spectralpass, passvis, visabsorption, absorptioncontaminating, contaminatinglabsolutions, labsolutionsanalysis, analysisperform
UV-1900i Plus UV-Vis Spectrophotometer
2025|Shimadzu|Brochures and specifications
C101-E181 UV-Vis Spectrophotometer UV-1900i Plus Navigate Your Way Refined User-Friendliness Easy-to-use touch-screen display Faster response speed with adoption of a new CPU Various Functions for Comfortable Daily Measurement User support with assist and shutdown/wakeup functions High Performance to Meet Diverse…
Key words
measurement, measurementfunction, functionfunctions, functionswakeup, wakeuplabsolutions, labsolutionsvis, visdata, datakinetics, kineticsinforms, informsshutdown, shutdownuser, userinstrument, instrumentmanagement, managementλdna, λdnacorrection