Summary

Importance of topic


Laboratory automation of sample preparation is critical for improving throughput, enhancing reproducibility, and reducing human error in chromatographic analyses.
The integration of specialized modules for dispensing, cartridge exchange, and autosampling with central control software streamlines complex workflows.

Objectives and overview


This document introduces the Clarity Control Module for the Spark Symbiosis system—a fully integrated sample preparation solution combining High Pressure Dispenser (HPD), Automatic Cartridge Exchanger (ACE), and Alias autosampler.
Key goals include direct communication, synchronized operation of all modules, and storage of preparation parameters alongside chromatographic data.

Methods and instrumentation


The Spark Symbiosis system components are interconnected via RS-232 (or optionally USB/LAN) and daisy-chained to a single COM port or network interface.
Detailed wiring of digital inputs/outputs and relay mappings enables external synchronization with detectors or digital input devices.
Configuration within Clarity software involves adding the Spark Symbiosis control module, auto-detecting module IDs, and assigning external start and ready signals.
Method development is split into three parts:
  • ACE Time Program and System settings define cartridge exchange sequences, valve switching, timed delays, and synchronization triggers.
  • HPD Time Program and System settings specify aspirate, dispense, pump steps, pressure limits, and auxiliary signals.
  • Alias User Program replaces traditional injection, wash, and output tabs, offering row-by-row commands for aspirate/dispense operations, needle moves, plate transfers, and freeze/unfreeze triggers.

Auxiliary dialogs support hardware configuration, device monitoring, panic stops, and service commands for maintenance tasks.

Main findings and discussion


The Clarity Control Module successfully unifies control of all Spark Symbiosis components, enabling:
  • Centralized parameter setting and method transfer for automated sample preparation.
  • Tight synchronization between dispenser, cartridge exchanger, and autosampler via software flags, digital I/O, and time stamps.
  • Real-time monitoring of module status, pressure, syringe volume, and cartridge usage.
  • Flexible method programming accommodating complex multi-step workflows with conditional waits and looping constructs.

Integration into chromatographic sequences allows each injection to be preceded by a tailored preparation routine and embeds preparation metadata directly into GLP-compliant reports.

Benefits and practical applications


Laboratories implementing this module can achieve:
  • Enhanced reproducibility by standardizing preparation routines.
  • Reduced hands-on time and faster turnaround for high-throughput environments.
  • Minimized cross-contamination via precise wash and valve protocols.
  • Traceable workflow documentation with synchronized timestamps and instrument logs.

Ideal applications include environmental testing, pharmaceutical QA/QC, food safety, and any context requiring robust solid-phase extraction or multi-step liquid handling.

Future trends and potential uses


Expanding control modules to additional prep devices will broaden automation capabilities.
Advanced scheduling, LIMS integration, and cloud-based monitoring may enable remote operation and predictive maintenance.
Implementation of AI-driven protocol optimization could adapt preparation steps in real time based on sample characteristics.
Enhanced digital I/O naming and custom mapping will simplify multi-instrument synchronization in complex laboratories.

Conclusion


The Spark Symbiosis Control Module for Clarity software offers a comprehensive, flexible solution for integrating high-throughput, automated sample preparation into chromatographic workflows.
By centralizing method creation, device monitoring, and data logging, it significantly improves efficiency, reproducibility, and compliance with quality standards.

Reference


No external literature references provided.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Clarity Control Module R-BIOPHARM RIDACREST
R-BIOPHARM RIDACREST Clarity Control Module ENG Code/Rev.: M210/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
ridacrest, ridacrestbiopharm, biopharmspark, sparkalias, aliashpd, hpddialog, dialogace, acecartridge, cartridgewait, waitclarity, claritydevice, devicesyringe, syringetray, traysetup, setupdefined
Clarity Control Module SPARK ALIAS
SPARK ALIAS Clarity Control Module ENG Code/Rev.: M102/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
alias, aliasspark, sparkcommunication, communicationautosampler, autosamplersetup, setupclarity, claritydialog, dialogtab, tabtray, trayvial, vialwash, washset, setsequence, sequencesyringe, syringevolume
Clarity Control Module SPARK INTEGRITY
SPARK INTEGRITY Clarity Control Module ENG Code/Rev.: M197/100A Date: 2025-05-12 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
spark, sparkintegrity, integrityneedle, needleautosampler, autosamplerdialog, dialogmove, movetray, traycommunication, communicationsyringe, syringeposition, positionclarity, claritystripper, stripperwash, washsetup, setuphomix
Clarity Control Module SPARK TRIATHLON
SPARK TRIATHLON Clarity Control Module ENG Code/Rev.: M117/90C Date: 2024-02-14 DataApex Ltd. Phone: +420 251 013 400 Petrzilkova 2583/13 [email protected] 158 00 Prague 5 www.dataapex.com Czech Republic ® are trademarks of DataApex Ltd. Microsoft® and WindowsTM are Clarity®, DataApex® and…
Key words
triathlon, triathlonspark, sparkwash, washsetup, setuptray, trayclarity, clarityautosampler, autosamplertab, tabsyringe, syringedialog, dialogneedle, needlevial, vialtimebase, timebasedefines, defineshome
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike