Capillary electrophoresis (CE) coupled with electrospray ionization mass spectrometry (ESI-MS) provides a rapid, sensitive, and high-resolution approach for detailed structural characterization of biopharmaceutical analytes. This technique addresses critical needs in antibody, antibody-drug conjugate (ADC), subunit, and peptide analysis essential for development, quality control, and regulatory compliance in the biopharma sector.
This application note outlines a comprehensive CE/ESI-MS workflow integrating Thermo Scientific Q Exactive hybrid quadrupole-Orbitrap mass spectrometers (Plus, HF, HF-X) with the 908 Devices ZipChip microfluidic system and BioPharma Finder software. The platform is designed to characterize intact antibodies, ADCs, antibody subunits, and peptides with minimal sample consumption and high throughput.
Advances in microfluidic CE-MS and Orbitrap detection are driving deeper proteoform profiling, real-time process monitoring, and automated high-throughput analyses. Coupling these platforms with advanced data analytics and machine learning will further enhance detection of low-abundance species and streamline biopharmaceutical development and quality control.
The Thermo Scientific ZipChip CE/ESI-MS solution, when paired with Q Exactive Orbitrap mass spectrometers and BioPharma Finder software, delivers a robust, fast, and sensitive workflow for comprehensive biopharmaceutical characterization. This integrated platform meets evolving demands for high-resolution separations, accurate mass measurements, and streamlined data analysis in biotherapeutic research and production.
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap, Capillary electrophoresis
IndustriesClinical Research
ManufacturerThermo Fisher Scientific
Summary
Importance of the topic
Capillary electrophoresis (CE) coupled with electrospray ionization mass spectrometry (ESI-MS) provides a rapid, sensitive, and high-resolution approach for detailed structural characterization of biopharmaceutical analytes. This technique addresses critical needs in antibody, antibody-drug conjugate (ADC), subunit, and peptide analysis essential for development, quality control, and regulatory compliance in the biopharma sector.
Study objectives and overview
This application note outlines a comprehensive CE/ESI-MS workflow integrating Thermo Scientific Q Exactive hybrid quadrupole-Orbitrap mass spectrometers (Plus, HF, HF-X) with the 908 Devices ZipChip microfluidic system and BioPharma Finder software. The platform is designed to characterize intact antibodies, ADCs, antibody subunits, and peptides with minimal sample consumption and high throughput.
Methodology and instrumentation
- ZipChip microfluidic CE separation: delivers fast separations (e.g., intact mAb variants in ≤3 min).
- Q Exactive hybrid quadrupole-Orbitrap MS (Plus, HF, HF-X) with BioPharma option: provides high-resolution accurate mass (HRAM) detection in HMR mode.
- BioPharma Finder software: supports sliding-window MS acquisition, Xtract deconvolution, and monoisotopic mass determination.
Main results and discussion
- Intact mAb analysis: rapid baseline separation of glycoforms and lysine-clipping variants with mass accuracies better than 10 ppm.
- ADC characterization: heterogenous trastuzumab emtansine DAR distribution determined in under 1 min from picogram to nanogram injections.
- mAb subunit profiling: IdeS digestion and reduction separate light chain, Fd′, and Fc/2 subunits with monoisotopic masses within 5 ppm of theoretical values.
- Peptide mapping: 10-minute CE-MS/MS run yields 98–100% sequence coverage of heavy and light chains from 1 ng input.
Benefits and practical applications
- Minimal sample consumption (pg–ng) and no extensive pre-treatment required.
- Accelerated workflows complement LC-MS for high-throughput screening, QA/QC, and detailed structural analysis.
- High sensitivity and resolution support precise glycoform, charge variant, and DAR determinations essential for regulatory filing.
Future trends and opportunities
Advances in microfluidic CE-MS and Orbitrap detection are driving deeper proteoform profiling, real-time process monitoring, and automated high-throughput analyses. Coupling these platforms with advanced data analytics and machine learning will further enhance detection of low-abundance species and streamline biopharmaceutical development and quality control.
Conclusion
The Thermo Scientific ZipChip CE/ESI-MS solution, when paired with Q Exactive Orbitrap mass spectrometers and BioPharma Finder software, delivers a robust, fast, and sensitive workflow for comprehensive biopharmaceutical characterization. This integrated platform meets evolving demands for high-resolution separations, accurate mass measurements, and streamlined data analysis in biotherapeutic research and production.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
ZipChip™ System for Selected Thermo Scientific™ Mass Spectrometers - for CE/ESI-MS Analyses
|Thermo Fisher Scientific|Presentations
ZipChip™ System for Selected Thermo Scientific™ Mass Spectrometers -- for CE/ESI-MS Analyses The world leader in serving science Content ZipChip System Introduction ZipChip Separation Mechanism Biopharmaceutical Application Examples Metabolomics Application and System Test Resources and Ordering Information 2 What is…
Key words
zipchip, zipchipexactive, exactivebiopharma, biopharmaabundance, abundancerelative, relativeseparation, separationassay, assaymab, mabbge, bgeachieved, achievedkit, kitsystem, systemintact, intactchip, chipnist
Quick screening of intact antibody and antibody-drug conjugates with integrated microfluidic capillary electrophoresis and mass spectrometry
2017|Thermo Fisher Scientific|Applications
APPLICATION NOTE 72358 Quick screening of intact antibody and antibodydrug conjugates with integrated microfluidic capillary electrophoresis and mass spectrometry Authors Chien-Hsun Alex Chen,1 Stephane Houel,1 Terry Zhang,1 Brian J. Agnew,2 Shanhua Lin,3 Kai Zhou,1 Jonathan Josephs,1 Aran Paulus,1 and Andreas…
Key words
mab, mabnist, nistadc, adcmass, massrelative, relativezipchip, zipchipvariants, variantsexactive, exactivebiopharma, biopharmaabundance, abundancelysine, lysinedrug, drugmodification, modificationconjugates, conjugatesintact
Characterization of intact monoclonal antibody with microfluidic chip electrophoresis mass spectrometry
2017|Thermo Fisher Scientific|Posters
POSTER NOTE 65000 Characterization of In Characterization of Chien-Hsun intact monoclonal antibody Chen1, Andreas Krupke2,with Stephane H 1Thermo Fisher Scientific, Chromatography and microfluidic chip electrophoresis mass spectrometry Authors Chien-Hsun Chen,1 Andreas Krupke,2 Stephane Houel,1 Aaron Bailey,1 Aran Paulus,1 Daniel Lopez-Ferrer,1…
Key words
relative, relativebiopharma, biopharmamab, mabintensity, intensityabundance, abundancemass, masschip, chipexactive, exactivefinder, finderglycosylated, glycosylatedmicrofluidic, microfluidicantibody, antibodyprotein, proteinterminal, terminaltic
ATE: Capillary Electrophoresis – Mass Spectrometry for Intact Mass Analysis of Antibodies and Antibody-Drug-Conjugate
2017|Thermo Fisher Scientific|Posters
Capillary Electrophoresis – Mass Spectrometry for Intact Mass Analysis of Antibodies and Antibody-Drug-Conjugates Michael Wenz1, Andreas Krupke1, Chien-Hsun Chen2, Stephane Houel2, Daniel Lopez-Ferrer2 and Aran Paulus2 1Thermo Fisher Scientific, Life Sciences Solutions, South San Francisco, CA 94080; 2Thermo Fisher Scientific,…
Key words
mab, mabnist, nistvariants, variantsbiopharma, biopharmaterminal, terminallysine, lysinecharge, chargeproteoforms, proteoformscharacterize, characterizeantibody, antibodyintact, intactmicrofluidic, microfluidicadcs, adcsfinder, finderconjugates