New innovations implemented on the Q Exactive HF mass spectrometer
Posters | 2017 | Thermo Fisher ScientificInstrumentation
The development of faster and more sensitive high resolution accurate mass spectrometers addresses critical demands in proteomics, metabolomics, biopharmaceutical analysis, and small molecule quantitation. Enhancements in ion transmission and scan speed directly translate into deeper proteome coverage, improved signal‐to‐noise ratios, and lower detection limits, supporting both discovery and routine quality control workflows.
This study describes design modifications and performance evaluation of a next‐generation hybrid quadrupole Orbitrap mass spectrometer. The main objectives were to double scan rates, boost ion flux, and reduce overhead times without compromising resolution or sensitivity. Comparative experiments benchmarked the new instrument against its predecessor in complex human cell digest analyses, monoclonal antibody profiling, and targeted small molecule assays.
Key hardware innovations introduced on the new instrument include:
Performance was assessed using data dependent acquisition of a HeLa protein digest, intact monoclonal antibody analysis under native and denaturing conditions, and targeted selected ion monitoring of spiked plasma standards. Resolution settings ranged from 7500 to 240000 at m/z 200, with injection times varied from 10 to 45 ms.
Major performance gains observed include:
The combination of higher scan rates and enhanced ion transmission enables deeper proteome profiling in shorter analysis windows, benefiting phosphoproteomics and post-translational modification studies. Improved spectral quality for intact biopharmaceuticals supports structural characterization of antibodies and fusion proteins. The extended dynamic range and lower detection limits facilitate trace-level quantitation in clinical and environmental monitoring.
Ongoing advances may include integration of parallel acquisition modes, enhanced multiplexing for single-cell proteomics, and real-time decision making driven by machine learning algorithms. Further miniaturization and automation are likely to expand deployment in regulated environments and point-of-care settings.
The new hybrid quadrupole Orbitrap mass spectrometer demonstrates significant improvements in ion handling and scanning performance. These enhancements yield substantial gains in proteomic coverage, biopharmaceutical analysis, and small molecule quantitation, paving the way for more efficient and sensitive workflows across diverse analytical applications.
1. Scheltema RA et al Mol Cell Proteomics 2014 Dec;13(12):3698–708
2. Kelstrup CD et al J Proteome Res 2014 Dec 5;13(12):6187–95
LC/HRMS, LC/MS, LC/MS/MS, LC/Orbitrap
IndustriesManufacturerThermo Fisher Scientific
Summary
Importance of the Topic
The development of faster and more sensitive high resolution accurate mass spectrometers addresses critical demands in proteomics, metabolomics, biopharmaceutical analysis, and small molecule quantitation. Enhancements in ion transmission and scan speed directly translate into deeper proteome coverage, improved signal‐to‐noise ratios, and lower detection limits, supporting both discovery and routine quality control workflows.
Aims and Overview of the Study
This study describes design modifications and performance evaluation of a next‐generation hybrid quadrupole Orbitrap mass spectrometer. The main objectives were to double scan rates, boost ion flux, and reduce overhead times without compromising resolution or sensitivity. Comparative experiments benchmarked the new instrument against its predecessor in complex human cell digest analyses, monoclonal antibody profiling, and targeted small molecule assays.
Methodology and Instrumentation
Key hardware innovations introduced on the new instrument include:
- A high capacity transfer tube and electrodynamic ion funnel to maximize ion transmission into the mass analyzer
- An advanced active beam guide to stabilize pressure and limit solvent cluster formation
- Upgraded forevacuum pumping system to accommodate source modifications
- Optimized timing overhead and charge state recognition routines
Performance was assessed using data dependent acquisition of a HeLa protein digest, intact monoclonal antibody analysis under native and denaturing conditions, and targeted selected ion monitoring of spiked plasma standards. Resolution settings ranged from 7500 to 240000 at m/z 200, with injection times varied from 10 to 45 ms.
Key Results and Discussion
Major performance gains observed include:
- Up to 2.8-fold increase in ion current after source modifications
- 3–5 times shorter ion injection times across positive and negative modes
- Maximum MS2 scan rate of 40 scans per second at 7500 resolution setting, double the predecessor
- 44% rise in unique peptide identifications and 11% more protein groups in bottom-up proteomics
- Equivalent peptide and protein group coverage achieved in half the gradient time (30 min versus 60 min)
- Approximately ten-fold improvement in signal-to-noise ratio for intact antibody analysis under native conditions
- Linear dynamic range spanning four orders of magnitude in targeted small molecule quantitation with detection limits down to 10 pg/ml and reproducibility below 15% CV
- Limit of quantitation up to five times lower than the previous generation instrument
Benefits and Practical Applications
The combination of higher scan rates and enhanced ion transmission enables deeper proteome profiling in shorter analysis windows, benefiting phosphoproteomics and post-translational modification studies. Improved spectral quality for intact biopharmaceuticals supports structural characterization of antibodies and fusion proteins. The extended dynamic range and lower detection limits facilitate trace-level quantitation in clinical and environmental monitoring.
Future Trends and Potential Applications
Ongoing advances may include integration of parallel acquisition modes, enhanced multiplexing for single-cell proteomics, and real-time decision making driven by machine learning algorithms. Further miniaturization and automation are likely to expand deployment in regulated environments and point-of-care settings.
Conclusion
The new hybrid quadrupole Orbitrap mass spectrometer demonstrates significant improvements in ion handling and scanning performance. These enhancements yield substantial gains in proteomic coverage, biopharmaceutical analysis, and small molecule quantitation, paving the way for more efficient and sensitive workflows across diverse analytical applications.
Reference
1. Scheltema RA et al Mol Cell Proteomics 2014 Dec;13(12):3698–708
2. Kelstrup CD et al J Proteome Res 2014 Dec 5;13(12):6187–95
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Thermo Scientific Q Exactive HF-X Hybrid Quadrupole-Orbitrap MS System - PRODUCT SPECIFICATIONS
2017|Thermo Fisher Scientific|Brochures and specifications
PRODUCT SPECIFICATIONS Thermo Scientific Q Exactive HF-X Hybrid Quadrupole-Orbitrap MS System • Scan speed up to 40 Hz with ultra-high-field Thermo Scientific™ Orbitrap™ mass analyzer technology • Resolution of up to 240,000 (FWHM) at m/z 200 • High Capacity Transfer…
Key words
ion, ionexactive, exactivemass, massorbitrap, orbitraphctt, hcttthermo, thermoflow, flowelectrodynamic, electrodynamicscan, scandata, dataahcd, ahcdvacuum, vacuumacquisition, acquisitionscientific, scientificquadrupole
Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer
2017|Thermo Fisher Scientific|Posters
Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer Tabiwang N. Arrey,1 Rosa Viner,2 Ryan D. Bomgarden,3 Eugen Damoc,1 Markus Kellmann,1 Thomas Moehring,1 and Alexander Harder1. 1Thermo Fisher Scientific (Bremen) GmbH, Hanna-Kunath-Str. 11, 28199 Bremen, 2Thermo Fisher…
Key words
exactive, exactivequantified, quantifiedidentified, identifiedavergae, avergaepeptides, peptidesgroups, groupsisolation, isolationprotein, proteinaverage, averagewidth, widthproteins, proteinsconsenseus, consenseusisobaric, isobaricconc, concworkflow
Performance Evaluation of a Modified Quadrupole Orbitrap Mass Spectrometer
2019|Thermo Fisher Scientific|Posters
Performance Evaluation of a Modified Quadrupole Orbitrap Mass Spectrometer Tabiwang N. Arrey1, Rosa Jersie-Christensen Rakownikow1, Julia Kraegenbring1, Kerstin Strupat1, Markus Kellmann1, Catharina Crone1, Thomas Moehring1, Alexander Harder1 1Thermo Fisher Scientific, Bremen, Bremen, Germany Results: The novel Orbitrap Exploris 480 mass…
Key words
protein, proteinpeptides, peptidesgroups, groupsyeast, yeastcompensention, compensentionnofiams, nofiamsunique, uniquenofaims, nofaimsmpi, mpimin, minaabg, aabgnew, newrouting, routingorbitrap, orbitrapfaims
Improving high-throughput Top-Down proteomics using a modified hybrid quadrupole-ultra-high-field-Orbitrap mass spectrometer
2017|Thermo Fisher Scientific|Posters
Improving high-throughput Top-Down proteomics using a modified hybrid quadrupole-ultra-high-field-Orbitrap mass spectrometer Eugen Damoc1, Kyle L. Fort2, Michiel van de Waterbeemd2, Sem Tamara2, Christian Thoeing1, Erik Cousijn1, Tabiwang Arrey1, Alexander Harder1, Albert J. R. Heck2 and Alexander Makarov1 Fisher Scientific (Bremen)…
Key words
ftms, ftmsabundance, abundancedda, ddatop, toprelative, relativedown, downsliding, slidingdeconvolution, deconvolutionhigh, highmasses, massesesi, esifull, fullwindow, windowxtract, xtractproteins