Peak Infinity XE 50X1 Series - User Manual
Manuals | 2019 | Peak ScientificInstrumentation
Reliable on-site gas generation has become essential in modern analytical laboratories. Continuous access to high-purity nitrogen supports a wide array of techniques – including liquid chromatography, mass spectrometry and sample preparation – while eliminating safety risks and logistical constraints associated with gas cylinders.
This user manual describes the Infinity XE 50X1 Series nitrogen generators by Peak Scientific Instruments. It aims to guide end users through:
The Infinity XE 50X1 Series employs pressure swing adsorption (PSA) to selectively remove oxygen and moisture from compressed air and deliver phthalate-free nitrogen at purities between 95 % and 99.5 %. Key instrument components include:
Extensive factory and field testing confirm:
The integrated oxygen alarm provides real-time purity monitoring and will automatically shut down the generator after 30 minutes of readings above a user-defined threshold, protecting critical applications.
Adoption of an on-site generator over traditional cylinders or bulk supply offers:
Emerging directions in lab gas generation include:
The Infinity XE 50X1 Series offers a reliable, cost-effective and user-friendly solution for on-demand nitrogen generation. Its robust construction, integrated safety features and low maintenance requirements make it a valuable asset for analytical, QA/QC and industrial laboratories seeking to streamline gas supply and support high-throughput workflows.
Peak Scientific Instruments Ltd, Infinity XE 50X1 Series User Manual Rev. 2, 2019.
Laboratory gases and gas generators
IndustriesManufacturerPeak Scientific
Summary
Importance of the topic
Reliable on-site gas generation has become essential in modern analytical laboratories. Continuous access to high-purity nitrogen supports a wide array of techniques – including liquid chromatography, mass spectrometry and sample preparation – while eliminating safety risks and logistical constraints associated with gas cylinders.
Study objectives and overview
This user manual describes the Infinity XE 50X1 Series nitrogen generators by Peak Scientific Instruments. It aims to guide end users through:
- Overview of product features and benefits
- Installation requirements and environmental considerations
- Operational controls, safety notices and commissioning steps
- Routine maintenance, troubleshooting and service schedules
Methodology and instrumentation
The Infinity XE 50X1 Series employs pressure swing adsorption (PSA) to selectively remove oxygen and moisture from compressed air and deliver phthalate-free nitrogen at purities between 95 % and 99.5 %. Key instrument components include:
- Dual adsorption columns with integrated oxygen analyser
- Built-in eco-mode for automatic air intake shut-off at low demand
- Adjustable outlet pressure regulator and on-demand flow control
- Safety-class I enclosure with CE-compliant electrical and EMC design
Main results and discussion
Extensive factory and field testing confirm:
- Stable nitrogen purity across a range of ambient temperatures (5–30 °C) and supply pressures (4.1–9.9 bar)
- Rapid start-up to operating purity in approximately 30 minutes
- Low maintenance requirements: annual filter and sieve inspections
- Quiet, mobile “plug-and-play” operation with minimal downtime
The integrated oxygen alarm provides real-time purity monitoring and will automatically shut down the generator after 30 minutes of readings above a user-defined threshold, protecting critical applications.
Benefits and practical applications
Adoption of an on-site generator over traditional cylinders or bulk supply offers:
- Cost savings through elimination of rental and transport fees
- Enhanced laboratory safety by removing high-pressure cylinders
- Continuous, uninterrupted gas supply on demand
- Flexibility to serve multiple instruments and laboratories from a single unit
Future trends and potential uses
Emerging directions in lab gas generation include:
- Remote monitoring and predictive maintenance via IoT connectivity
- Integration with laboratory information management systems (LIMS)
- Higher-capacity and multi-gas modular generator platforms
- Advanced eco-modes for improved energy efficiency and carbon footprint reduction
Conclusion
The Infinity XE 50X1 Series offers a reliable, cost-effective and user-friendly solution for on-demand nitrogen generation. Its robust construction, integrated safety features and low maintenance requirements make it a valuable asset for analytical, QA/QC and industrial laboratories seeking to streamline gas supply and support high-throughput workflows.
Reference
Peak Scientific Instruments Ltd, Infinity XE 50X1 Series User Manual Rev. 2, 2019.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Peak Solaris XE - User Manual
2020|Peak Scientific|Manuals
Solaris XE User Manual Copyright © Peak Scientific Instruments Ltd 2020 — Solaris XE User Manual Rev 5 RSID 2302 EN —21/07/2020 Contents Change History 3 How to use this Manual 3 Warranties and Liabilities 4 Safety Notices 5 Symbols…
Key words
generator, generatorsolaris, solariscaution, cautionpeak, peakwarning, warningprotected, protectedcouttie, couttieliam, liamair, airfascia, fasciaunpacking, unpackingyellow, yellowdeclaration, declarationpower, powernitrogen
Peak Scientific Genius XE SMZ - User Manual
2021|Peak Scientific|Manuals
Genius XE SMZ User Manual Genius XE SMZ User Manual Rev 1 RSID 4041 EN 09/02/21 Register Product to Operate To begin operation you will need to register your generator. You can do so by visiting www.peakscientific.com/activate or by downloading…
Key words
generator, generatorsmz, smzservice, servicewarning, warninggenius, geniuspeak, peakcaution, cautionfault, faulttank, tankhmi, hmiprotected, protectedindication, indicationcodes, codesscreens, screensdeclaration
Genius XE (All Models) User Manual
2020|Peak Scientific|Manuals
Genius XE (All Models) User Manual Copyright © Peak Scientific Instruments Ltd 2020 — GeniusXE User Manual Rev 9 RSID 2299 EN —18/02/2020 Register Product to Operate To begin operation you will need to register your generator. You can do…
Key words
screen, screengenerator, generatorservice, servicehome, homexxxx, xxxxwarning, warningcouttie, couttieliam, liamscreens, screensoverdue, overduepeak, peakpsi, psierror, erroreco, ecocaution
Peak MS Table (All Models) - User Manual
2017|Peak Scientific|Manuals
MS Table (All Models) User Manual Copyright © Peak Scientific Instruments Ltd 2017 — MS Table User Manual | Rev 2 | PN UM-0012| RSID 1927 | EN —25/08/2017 Contents Change History How to use this Manual Introduction Warranties and…
Key words
generator, generatormaximum, maximumair, airoutput, outputpeak, peakwarning, warningoutlet, outletcaution, cautionpressure, pressurecurtain, curtainprotected, protectedconnection, connectionyour, yourfittings, fittingsscientific