Agilent 6400 Series LC/TQ - Site Preparation Checklist
Manuals | 2020 | Agilent TechnologiesInstrumentation
Correct site preparation is critical for installing high-performance LC/TQ systems. Proper planning ensures reliable operation, accurate analytical data, extended instrument lifetime, and compliance with safety and environmental standards.
This checklist outlines all customer responsibilities and facility requirements prior to installing the Agilent 6400 Series LC/TQ. It covers space planning, environmental conditions, power and ground requirements, consumables, gas supplies, and exhaust venting.
The document is organized into sectional requirements:
Key specifications include:
Adhering to these requirements minimizes installation delays, reduces troubleshooting, and ensures optimal mass spectrometer performance in quantitative trace analysis, environmental monitoring, pharmaceutical QA/QC, and proteomics.
Next-generation LC/TQ installations will leverage integrated self-diagnostics, remote calibration, modular source assemblies, reduced footprint designs, and greener gas generation systems to further reduce downtime and operational costs.
Thorough site preparation following Agilent’s checklist is essential to achieve reliable, precise, and safe LC/TQ operation over the instrument’s life cycle.
LC/MS, LC/MS/MS, LC/QQQ
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
Correct site preparation is critical for installing high-performance LC/TQ systems. Proper planning ensures reliable operation, accurate analytical data, extended instrument lifetime, and compliance with safety and environmental standards.
Goals and Study Overview
This checklist outlines all customer responsibilities and facility requirements prior to installing the Agilent 6400 Series LC/TQ. It covers space planning, environmental conditions, power and ground requirements, consumables, gas supplies, and exhaust venting.
Methodology and Instrumentation
The document is organized into sectional requirements:
- Physical dimensions and weight limits for the G6470A and G6495C LC/TQ, foreline pumps, and ion sources.
- Ambient temperature, humidity, and altitude specifications to maintain calibration stability.
- Electrical supply details, including voltage tolerances, outlet count, grounding, and maximum power consumption.
- Nitrogen supply purity, pressure, and flow rates for both spray chamber and collision cell gases.
- Exhaust venting recommendations to safely remove pump fumes and solvent vapors.
Main Results and Discussion
Key specifications include:
- Bench clearance of at least 30 cm on each side and vibration-free support for weights up to 271 lbs.
- Operating temperature range of 15–35 °C with humidity under 85 % at 35 °C and altitude limits up to 3,300 m.
- 200–240 VAC single-phase or Wye power, two 15 A outlets per instrument, with isolated earth grounds and THD below 3 %.
- Main nitrogen supply ≥99.5 % purity, 5.5–6.8 bar pressure, and up to 50 L/min flow; collision cell nitrogen at ≥99.999 % purity, 1–2 bar, minimal flow 0.001 L/min.
- Separate negative-pressure exhausts for foreline pump and spray chamber, ≥30 L/min combined flow, 1/2" tubing.
Benefits and Practical Applications
Adhering to these requirements minimizes installation delays, reduces troubleshooting, and ensures optimal mass spectrometer performance in quantitative trace analysis, environmental monitoring, pharmaceutical QA/QC, and proteomics.
Future Trends and Opportunities
Next-generation LC/TQ installations will leverage integrated self-diagnostics, remote calibration, modular source assemblies, reduced footprint designs, and greener gas generation systems to further reduce downtime and operational costs.
Conclusion
Thorough site preparation following Agilent’s checklist is essential to achieve reliable, precise, and safe LC/TQ operation over the instrument’s life cycle.
Instrumentation Used
- Agilent 6400 Series Triple Quadrupole LC/MS: G6470A and G6495C
- Foreline pumps: MS40+ and MS120
- Ionization sources: Agilent Jet Stream, APCI, APPI, MMI, ESI, NSI
References
- Agilent Technologies. Agilent 6400 Series LC/TQ Site Preparation Checklist, Revision 8.1, April 2020.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 6400 Series LC/TQ - Site Preparation Checklist
2020|Agilent Technologies|Manuals
Agilent 6400 Series LC/TQ Site Preparation Checklist Thank you for purchasing an Agilent 6400 LC/TQ. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is…
Key words
checklist, checklistsite, sitenitrogen, nitrogenspecial, specialhydrocarbon, hydrocarbonnotes, notessource, sourcefree, freeexhaust, exhaustsupplies, suppliescustomer, customerpreparation, preparationforeline, forelineinstrument, instrumentmaximum
Agilent 6400 Series Triple Quad LC/MS - Site Preparation Checklist
2017|Agilent Technologies|Manuals
Agilent 6400 Series Triple Quad LC/MS Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation…
Key words
checklist, checklistsite, sitenitrogen, nitrogenhydrocarbon, hydrocarbonspecial, specialground, groundnotes, notesfree, freetechnologies, technologiesagilent, agilentmodel, modelline, linepreparation, preparationgenerator, generatorinstrument
Agilent G6475A and 6495D LC/TQ Site Preparation Checklist
2023|Agilent Technologies|Manuals
Agilent CrossLab Start Up Services Agilent G6475A and 6495D LC/TQ Site Preparation Checklist Thank you for purchasing an instrument from Agilent Technologies. CrossLab Start Up is focused on helping customers shorten the time it takes to start realizing the full…
Key words
special, specialnitrogen, nitrogenground, groundrequirements, requirementsline, linehydrocarbon, hydrocarbonservice, servicesource, sourcecustomer, customernotes, notessite, sitefree, freeinstrument, instrumentengineer, engineerexhaust
Agilent Ultivo Hardware - Site Preparation Checklist
2017|Agilent Technologies|Manuals
Ultivo Hardware Site Preparation Checklist Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation is the key first…
Key words
ultivo, ultivochecklist, checklistground, groundsite, siteagilent, agilentspecial, specialhardware, hardwaretechnologies, technologiesnotes, notesline, lineexhaust, exhaustinstrument, instrumentmodel, modelpreparation, preparationforeline