Automated, Kit-Based Sample Preparation Strategy for LC-MS Quantification of Cetuximab in Rat Plasma
Applications | 2018 | WatersInstrumentation
Monoclonal antibodies (mAbs) are a rapidly growing class of therapeutics with high target specificity, extended half-lives, and broad clinical applications in oncology, immunology, and infectious diseases. Accurate quantification of mAbs in biological matrices such as plasma is critical for pharmacokinetic studies, dose optimization, biosimilar development, and regulatory compliance.
This work presents a fully automated, kit-based sample preparation and LC-MS/MS quantification strategy for cetuximab in rat plasma. The workflow employs ProteinWorks Auto-eXpress High 5 Digest and µElution SPE Clean-Up Kits on a Hamilton Microlab STAR liquid handler to achieve a low limit of quantification (LLOQ) of 100 ng/mL and robust assay performance.
Sample Preparation and Automation:
LC-MS/MS Conditions:
The automated workflow processed 40 µL plasma samples in approximately 6 hours. Key performance metrics:
The kit-based, automated approach delivers:
Emerging directions include:
This study demonstrates that a fully automated, kit-based sample preparation platform on the Hamilton STAR, combined with optimized LC-MS/MS methods, enables sensitive, accurate, and reproducible quantification of cetuximab in plasma. The streamlined workflow supports efficient biotherapeutic bioanalysis and can be readily extended to other large-molecule drugs.
Sample Preparation, Consumables, LC/MS, LC/MS/MS, LC/QQQ
IndustriesClinical Research
ManufacturerWaters
Summary
Importance of the Topic
Monoclonal antibodies (mAbs) are a rapidly growing class of therapeutics with high target specificity, extended half-lives, and broad clinical applications in oncology, immunology, and infectious diseases. Accurate quantification of mAbs in biological matrices such as plasma is critical for pharmacokinetic studies, dose optimization, biosimilar development, and regulatory compliance.
Aims and Study Overview
This work presents a fully automated, kit-based sample preparation and LC-MS/MS quantification strategy for cetuximab in rat plasma. The workflow employs ProteinWorks Auto-eXpress High 5 Digest and µElution SPE Clean-Up Kits on a Hamilton Microlab STAR liquid handler to achieve a low limit of quantification (LLOQ) of 100 ng/mL and robust assay performance.
Methodology and Instrumentation
Sample Preparation and Automation:
- Surrogate peptide bottom-up approach using tryptic digestion, reduction, and alkylation.
- ProteinWorks Auto-eXpress High 5 Digest Kit for streamlined digestion on the STAR.
- ProteinWorks µElution SPE Clean-Up Kit for peptide enrichment and cleanup.
- Internal standard SILuMAB (13C6-15N4 arginine and 13C6-15N2 lysine labeled) spiked at 16 µg/mL to correct for variability.
- Automation deck includes heater shakers for incubation, a plate sealer, piercing module, and vacuum manifold.
LC-MS/MS Conditions:
- Instrument: Waters ACQUITY UPLC System coupled to Xevo TQ-S MS (ESI+, MRM).
- Column: Peptide BEH C18 (300 Å, 1.7 µm, 2.1 × 150 mm) at 55 °C.
- Mobile phases: 0.1% formic acid in water (A) and acetonitrile (B); gradient from 2% to 45% B over 7 min; flow 0.3 mL/min.
- MRM transitions optimized for unique cetuximab peptides (e.g., DILLTQSPVILSVSPGER, YASESISGIPSR, SQVFFK) and corresponding SILuMAB peptides.
- Data acquisition and quantification via MassLynx v4.1 and TargetLynx software.
Main Results and Discussion
The automated workflow processed 40 µL plasma samples in approximately 6 hours. Key performance metrics:
- LLOQ of 100 ng/mL for cetuximab signature peptides with clear chromatographic separation and minimal interference.
- Linear dynamic range 0.10–250 µg/mL (r2 > 0.99) with 1/x weighting.
- Mean accuracy near 99–100% across seven peptides and QC levels.
- Precision (CV) ≤ 15% for all QC concentrations.
- Standard curves spanned three orders of magnitude, supporting high-throughput pharmacokinetic studies.
Benefits and Practical Applications
The kit-based, automated approach delivers:
- Reduced hands-on time and manual steps to minimize error and variability.
- Reproducible digestion and cleanup enabling novice users to generate reliable data.
- High sensitivity and wide dynamic range suitable for preclinical and biosimilar research.
- Compatibility with other therapeutic proteins by adapting surrogate peptide panels.
Future Trends and Applications
Emerging directions include:
- Multiplexed quantification of multiple mAbs or biomarkers in a single run.
- Integration with immunoaffinity enrichment to push LLOQs lower for clinical studies.
- Miniaturized, high-density sample prep platforms for ultra-high throughput.
- Real-time data processing and digital workflows for regulatory compliance and QC labs.
Conclusion
This study demonstrates that a fully automated, kit-based sample preparation platform on the Hamilton STAR, combined with optimized LC-MS/MS methods, enables sensitive, accurate, and reproducible quantification of cetuximab in plasma. The streamlined workflow supports efficient biotherapeutic bioanalysis and can be readily extended to other large-molecule drugs.
Used Instrumentation
- Hamilton Microlab STAR automated liquid handler
- ProteinWorks Auto-eXpress High 5 Digest Kit
- ProteinWorks µElution SPE Clean-Up Kit
- Waters ACQUITY UPLC System, Peptide BEH C18 column
- Waters Xevo TQ-S Mass Spectrometer
- MassLynx v4.1 and TargetLynx software
Reference
- Grand View Research (2017) Biologics market size worth $399.5 billion by 2025.
- Grand View Research (2016) Monoclonal antibodies market size worth $138.6 billion by 2024.
- Marnett Research Laboratory, Vanderbilt University (2017) Cetuximab overview.
- FDA Guidance for Industry: Bioanalytical Method Validation, CDER.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
AUTOMATED SAMPLE PREPARATION FOR HYBRID LC-MS/MS PROTEIN QUANTIFICATION
2020|Waters|Posters
AUTOMATED SAMPLE PREPARATION FOR HYBRID LC-MS/MS PROTEIN QUANTIFICATION Paula Orens and Mary Lame Waters Corporation, 34 Maple St Milford, MA 01757 INTRODUCTION METHODS Sample Preparation Whole Plasma Samples Using the Waters ProteinWorks™ (ProteinWorks) Auto-eXpress Direct Digest and µElution SPE CleanUp…
Key words
automated, automatedpeptide, peptidedigestion, digestionetanercept, etanerceptdilltqspvilsvspger, dilltqspvilsvspgerproteinworks, proteinworksquantification, quantificationarea, areaprotein, proteinyase, yaseyasesisgipsr, yasesisgipsrlinear, linearnormalized, normalizeddill, dillsqvffk
Quantification of Rituximab in Plasma Using an Automated and Standardized Kit-Based Approach
2018|Waters|Applications
[ APPLICATION NOTE ] Quantification of Rituximab in Plasma Using an Automated and Standardized Kit-Based Approach Mary Lame, Paula Orens, and Steven Calciano Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION Automated and standardized approach In the past decade, monoclonal…
Key words
proteinworks, proteinworksrituximab, rituximabglewigaiypgngdtsynqk, glewigaiypgngdtsynqkstandardized, standardizedexpress, expressvdnalqsgnsqesvteqdsk, vdnalqsgnsqesvteqdskstar, starhamilton, hamiltondigest, digestmicrolab, microlabkit, kitquantification, quantificationplasma, plasmaautomated, automatedµelution
Accurate and Sensitive LC-MS/MS Quantification of Adalimumab in Serum/Plasma: Impact of Sample Preparation on Method Performance
2018|Waters|Applications
[ APPLICATION NOTE ] Accurate and Sensitive LC-MS/MS Quantification of Adalimumab in Serum/Plasma: Impact of Sample Preparation on Method Performance Caitlin Dunning, Mary Lame, Steven Calciano, and Kelly Doering Waters Corporation, Milford, MA, USA APPLICATION BENEFITS ■■ ■■ Speed and…
Key words
adalimumab, adalimumabserum, serumglewvsaitwnsghidyadsvegr, glewvsaitwnsghidyadsvegrquantification, quantificationnylawyqqkpgk, nylawyqqkpgkproteinworks, proteinworksapytfgqgtk, apytfgqgtkplasma, plasmaspe, speprotein, proteinpeptide, peptideaccurate, accuratedigestion, digestiondigest, digestsensitive
Automated and Standardized, Kit-Based Workflow for Protein Quantification
2018|Waters|Applications
[ TECHNOLOGY BRIEF ] Automated and Standardized, Kit-Based Workflow for Protein Quantification Mary Lame, Paula Orens, and Steven Calciano Waters Corporation, Milford, MA, USA Bottom-up, protein quantification workflows are time consuming and complex. A need exists for simpler and standardized…
Key words
proteinworks, proteinworkscrp, crpexpress, expressdigest, digestinfliximab, infliximabkits, kitsasqf, asqfafv, afvauto, autosins, sinsdill, dilllees, leesesd, esdautomated, automatedtryptic