Plasmion SICRIT® SC-30X Ionization Set - Hardware and Operations Manual
Manuals | 2020 | PlasmionInstrumentation
The SICRIT® SC-30X Ionization Set introduces a versatile and soft ionization approach suitable for direct coupling with mass spectrometers or chromatographic systems. By generating a cold dielectric‐barrier plasma at atmospheric pressure, this technology enables rapid, solvent-free analysis of volatile and semi-volatile compounds. Its ambient and flow-through design supports applications in environmental monitoring, food safety, pharmaceutical screening and quality control.
This manual documents the design, installation, operation and maintenance of the SICRIT® SC-30 Control Unit and Ion Source. It aims to guide laboratory professionals through safe setup, parameter adjustment, module integration and troubleshooting. The document covers technical specifications, user interface navigation, compliance with safety directives and replacement procedures for consumable parts.
The SC-30X Ionization Set comprises:
Installation procedures ensure correct electrical and mechanical connections, compliance with EU Low Voltage (2014/35/EU), EMC (2014/30/EU) and RoHS (2011/65/EU) directives. The user interface employs a color-coded LED ring and menu tabs for high-voltage, module control and status monitoring.
Users can adjust ionization voltage (up to 3000 Vpp) and frequency (10–50 kHz) in real time to optimize plasma conditions. The GC/SPME Module is controlled by a PI heater, achieving stable temperatures within 10 minutes. Error messages guide corrective actions—covering low HV output, amplifier faults, thermofuse trips and SD-card issues. Maintenance involves cleaning external surfaces, replacing 2.0 A fuses, and exchanging the DBD core after ~1000 h or when sensitivity declines.
Advances may include integration with automated sampling systems, closed-loop plasma control leveraging machine learning, expanded compatibility with additional MS platforms, and miniaturized control units for field-deployable monitoring. Further development of specialized modules (e.g., thermal desorption, microextraction) will broaden application scope in metabolomics, forensics and on-site environmental screening.
The SICRIT® SC-30X Ionization Set delivers a robust, user-friendly solution for soft plasma ionization at ambient pressure. Its flexible interface, intuitive control software and detailed maintenance guidelines support reliable, high-throughput chemical analysis across research and QA/QC labs.
GC/MSD, LC/MS
IndustriesManufacturerPlasmion
Summary
Significance of Topic
The SICRIT® SC-30X Ionization Set introduces a versatile and soft ionization approach suitable for direct coupling with mass spectrometers or chromatographic systems. By generating a cold dielectric‐barrier plasma at atmospheric pressure, this technology enables rapid, solvent-free analysis of volatile and semi-volatile compounds. Its ambient and flow-through design supports applications in environmental monitoring, food safety, pharmaceutical screening and quality control.
Study Objectives and Overview
This manual documents the design, installation, operation and maintenance of the SICRIT® SC-30 Control Unit and Ion Source. It aims to guide laboratory professionals through safe setup, parameter adjustment, module integration and troubleshooting. The document covers technical specifications, user interface navigation, compliance with safety directives and replacement procedures for consumable parts.
Methodology and Instrumentation
The SC-30X Ionization Set comprises:
- SC-30 Control Unit: 100–240 VAC input, 2 × 0–1100 VAC high-voltage outputs (10–50 kHz), 24 VDC module port, integrated OLED display and rotary encoder, Ethernet for remote control, IP30 protection.
- SICRIT® Ion Source: Compact stainless steel and PEEK body, quick-lock mount for MS interface, 6 mm Swagelok sampling inlet, DBD core requiring periodic replacement, temperature resistance up to 250 °C.
- Optional Modules (e.g., GC/SPME heating): 24 VDC, 100 W output for sample preconditioning.
Installation procedures ensure correct electrical and mechanical connections, compliance with EU Low Voltage (2014/35/EU), EMC (2014/30/EU) and RoHS (2011/65/EU) directives. The user interface employs a color-coded LED ring and menu tabs for high-voltage, module control and status monitoring.
Main Results and Discussion
Users can adjust ionization voltage (up to 3000 Vpp) and frequency (10–50 kHz) in real time to optimize plasma conditions. The GC/SPME Module is controlled by a PI heater, achieving stable temperatures within 10 minutes. Error messages guide corrective actions—covering low HV output, amplifier faults, thermofuse trips and SD-card issues. Maintenance involves cleaning external surfaces, replacing 2.0 A fuses, and exchanging the DBD core after ~1000 h or when sensitivity declines.
Benefits and Practical Applications
- Gentle ionization minimizes fragmentation, preserving molecular ions for structural analysis.
- Ambient operation reduces sample preparation and solvent use.
- Modular design allows coupling with GC, HPLC and atmospheric sampling accessories.
- Real-time parameter tuning increases flexibility for diverse analyte classes.
Future Trends and Opportunities
Advances may include integration with automated sampling systems, closed-loop plasma control leveraging machine learning, expanded compatibility with additional MS platforms, and miniaturized control units for field-deployable monitoring. Further development of specialized modules (e.g., thermal desorption, microextraction) will broaden application scope in metabolomics, forensics and on-site environmental screening.
Conclusion
The SICRIT® SC-30X Ionization Set delivers a robust, user-friendly solution for soft plasma ionization at ambient pressure. Its flexible interface, intuitive control software and detailed maintenance guidelines support reliable, high-throughput chemical analysis across research and QA/QC labs.
Used Instrumentation
- SICRIT® SC-30 Control Unit
- SICRIT® Ion Source with DBD Plasma Core
- GC/SPME Heating Module (optional)
- High-Voltage Cables and Mounting Tool
- MS Interface Adapter (e.g., Thermo Fisher Orbitrap transfer capillary)
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Plasmion SICRIT® GC/SPME Module - Installation and Operations Manual
2020|Plasmion|Manuals
Installation and Operations Manual SICRIT® GC/SPME Module Release Jan 2020 Plasmion GmbH – Am Mittleren Moos 48 – 86167 Augsburg - Deutschland - Installation and Operations Manual SICRIT® GC/SPME-Module Version 0.3 This manual must be to be stored carefully and…
Key words
sicrit, sicritspme, spmemodule, moduleoperations, operationsinstallation, installationmanual, manualtransferline, transferlineplasmion, plasmionrail, railswagelok, swagelokliner, linerinsert, insertinlet, inlettight, tightcarefully
Plasmion SICRIT® Interface AX1/2 - Installation Manual
2020|Agilent Technologies|Manuals
Installation Manual SICRIT® Interface AX1/2 for Agilent LC-MS instruments Release January 2020 Plasmion GmbH – Am Mittleren Moos 48 - 86167 Augsburg - Germany Installation Manual SICRIT® Interface AX1/2 Version 0.2 This manual has to be stored carefully and must…
Key words
sicrit, sicritadaptor, adaptorattention, attentionresistive, resistivespacer, spacersource, sourcetighten, tightenmanual, manualjam, jamscrewing, screwingceramic, ceramicclockwise, clockwisesafety, safetyinterlock, interlockion
Plasmion SICRIT® Interface TX2/3 - Installation Manual
2020|Thermo Fisher Scientific|Manuals
Installation Manual SICRIT® Interface TX2/3 for Thermo Fisher LTQ, LTQ Velos, Orbitrap Elite and Exactive Series Release January 2020 Plasmion GmbH – Am Mittleren Moos 48 - 86167 Augsburg - Germany Installation Manual SICRIT® Interface TX2/3 Version 0.2 This manual…
Key words
sicrit, sicritinterlock, interlocksafety, safetycapillary, capillarymanual, manuallaunching, launchingattention, attentionrecommended, recommendedoperation, operationcap, capinlet, inletmanuals, manualsresponsibility, responsibilityinstallation, installationdismounted
Plasmion SICRIT® Interface SX1 - Installation Manual
2020|Plasmion|Manuals
Installation Manual SICRIT® Interface SX1 for SCIEX LC-MS instruments Release January 2020 Plasmion GmbH – Am Mittleren Moos 48 - 86167 Augsburg - Germany Installation Manual SICRIT® Interface SX1 Version 0.2 This manual has to be to be stored carefully…
Key words
sicrit, sicritinterlock, interlocksource, sourceadaptor, adaptorsciex, sciexion, ioninterface, interfacediscs, discsspacer, spacerinstallation, installationmanual, manualventuri, venturidistance, distancedial, dialsure