Shim-pack GWS Series INSTRUCTION MANUAL

Manuals |  | ShimadzuInstrumentation
Consumables, LC columns
Industries
Manufacturer
Shimadzu

Summary

Importance of Topic


High-performance packed columns are critical for achieving sharp, reproducible peaks and reliable quantitation in HPLC workflows.
They directly impact method sensitivity, resolution, and throughput across pharmaceutical, environmental and quality control laboratories.

Study Objectives and Overview


This instruction manual aims to outline best practices for Shim-pack GWS series packed columns, covering installation, handling, performance monitoring and storage to secure optimal lifespan and chromatographic stability.

Methodology and Used Instrumentation


Shim-pack GWS columns undergo stringent QC tests to ensure lot-to-lot consistency in reagent purity, packing efficiency and selectivity.
Key instrumentation and consumables:
  • HPLC system with degassing capability and pressure monitoring up to 20 MPa
  • PEEK or stainless steel (SUS) tubing, inner diameter 0.25–0.3 mm, outer diameter 1.6 mm
  • 0.45 μm membrane filters for mobile phase and sample filtration
  • Ghost Trap DS particulate and contaminant trap between pump and injector
  • Guard column placed at column inlet to protect against clogging

Main Results and Discussion


Shim-pack GWS columns demonstrate high reproducibility and stability when operated within pH 2.0–7.5 and below 20 MPa.
Proper flushing of flow lines and elimination of air bubbles prevents baseline noise and drift.
Minimizing dead volume by using short, correct-diameter tubing and secure PEEK male nut fittings reduces peak tailing in early eluting compounds.
Preventive measures such as sample pre-filtration and guard columns effectively guard against backpressure increases and split peaks caused by particulates.

Benefits and Practical Applications


Reliable retention times and sharp peak shapes improve quantitative accuracy in routine assays.
Extended column lifetime reduces downtime and cost in high-throughput environments.
Broad compatibility with common organic solvents and buffers facilitates method transfer across laboratories.

Future Trends and Opportunities


Development of wider pH-range stationary phases to extend applications into more extreme conditions.
Advancements in sub-2 μm and core-shell particles for higher efficiency and faster separations.
Integration with automated sample preparation and inline filtration for fully automated workflows.

Conclusion


Adhering to recommended installation, operation and storage guidelines ensures the high performance and longevity of Shim-pack GWS HPLC columns.
Consistent QC-driven manufacturing, along with preventive maintenance strategies, enables robust, reproducible chromatographic results.

Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.

Downloadable PDF for viewing
 

Similar PDF

Toggle
Shim-pack GIST/GISS Series INSTRUCTION MANUAL
ERAD-0001-9007 High Performance Packed Column for HPLC Shim-pack GIST/GISS Series INSTRUCTION MANUAL  Introduction  Column Installation To maintain and maximize peak performance of Shim-pack GIST/GISS series columns, and to ensure the long life and stability of columns, please read…
Key words
gist, gistshim, shimpack, packgiss, gisscolumn, columnphenyl, phenylcolumns, columnsoperating, operatingseries, seriesgroups, groupspressure, pressuresolvent, solventeluent, eluentperformance, performanceprecautions
High Performance Packed Column for HPLC - Scepter Series
ERAD_0001-9043A High Performance Packed Column for HPLC Shim-pack Scepter Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter series columns, and to ensure the…
Key words
scepter, sceptershim, shimpack, packcolumn, columnprecautions, precautionspfpp, pfppphenyl, phenylpressure, pressureguard, guardeluent, eluentperformance, performancecolumns, columnsinstalling, installingvalve, valvepreparative
High Performance Packed Column for HPLC - Scepter Diol-HILIC Series
ERAD-0001-9045 High Performance Packed Column for HPLC Shim-pack Scepter Diol-HILIC Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter fittings are connected properly to…
Key words
scepter, sceptercolumn, columnshim, shimdiol, diolpack, packhilic, hilicpressure, pressuresolvent, solventmobile, mobileprecautions, precautionsinstalling, installingoperating, operatingprecipitation, precipitationshould, shouldfittings
Shim-pack - Scepter Diol-HILIC Series - INSTRUCTION MANUAL
ASPM-0033A High Performance Packed Column for HPLC Shim-pack Scepter Diol-HILIC Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter fittings are connected properly to…
Key words
scepter, sceptercolumn, columnshim, shimdiol, diolpack, packhilic, hilicpressure, pressuresolvent, solventprecautions, precautionsmobile, mobileinstalling, installingoperating, operatingprecipitation, precipitationshould, shouldfittings
Other projects
GCMS
ICPMS
Follow us
More information
WebinarsAbout usContact usTerms of use
LabRulez s.r.o. All rights reserved. Content available under a CC BY-SA 4.0 Attribution-ShareAlike