Shim-pack GIS Series INSTRUCTION MANUAL
Manuals | | ShimadzuInstrumentation
HPLC column selection and maintenance directly affects analytical performance, method reproducibility and operational costs. A clear understanding of column characteristics and proper handling protocols is essential for laboratories across pharmaceutical, environmental and industrial sectors.
This instruction manual aims to provide comprehensive guidance for the Shim-pack GIS series of high-performance packed columns, covering optimal chromatographic results, extended column lifetime and stability under diverse conditions.
Proper solvent switching protocols require intermediate solvent flushing to avoid packing damage when changing mobile phase polarity. Flow rate and pressure limits vary by column dimensions and particle size, with UHPLC formats demanding precise low-volume connections to minimize extra-column effects. Column clogging due to sample particulates or degraded pump seals can be mitigated by adequate filtration and guard cartridges.
The Shim-pack GIS series delivers high reproducibility, reduced method development time and compatibility with reversed-phase, normal-phase and HILIC modes, supporting QC, routine analyses and complex research separations.
Emerging developments may include novel stationary phase chemistries for enhanced selectivity, sub-2 µm and core-shell particles for faster UHPLC, AI-driven method optimization and expanded MS compatibility through low-bleed trap devices.
Adhering to recommended installation, operation and maintenance practices ensures consistent performance and extended service life of Shim-pack GIS columns, with proper system configuration and preventative measures vital for reliable HPLC outcomes.
Shimadzu Corporation. Shim-pack GIS Series Instruction Manual (ERAD-0001-9008A).
Consumables, LC columns
IndustriesManufacturerShimadzu
Summary
Significance of the Topic
HPLC column selection and maintenance directly affects analytical performance, method reproducibility and operational costs. A clear understanding of column characteristics and proper handling protocols is essential for laboratories across pharmaceutical, environmental and industrial sectors.
Objectives and Overview of the Manual
This instruction manual aims to provide comprehensive guidance for the Shim-pack GIS series of high-performance packed columns, covering optimal chromatographic results, extended column lifetime and stability under diverse conditions.
Methodology and Instrumentation
- Quality Control: Each column undergoes rigorous testing of selectivity, efficiency, material purity and lot-to-lot reproducibility.
- Column Specifications: Details on bonded phase chemistry, pore size (9–29 nm), surface area (450 m2/g for RP-Shield), carbon content and end-capping treatment for various modes.
- Shipping Solvents: Defined mixtures per column type to preserve stationary phase integrity (e.g., water/acetonitrile 35/65 v/v for C18).
- System Setup: Recommended PEEK or stainless-steel tubing dimensions, injector bypass valves, 0.45 µm membrane filters and guard columns or Ghost Trap DS to protect columns from particulates.
Main Results and Discussion
Proper solvent switching protocols require intermediate solvent flushing to avoid packing damage when changing mobile phase polarity. Flow rate and pressure limits vary by column dimensions and particle size, with UHPLC formats demanding precise low-volume connections to minimize extra-column effects. Column clogging due to sample particulates or degraded pump seals can be mitigated by adequate filtration and guard cartridges.
Benefits and Practical Applications
The Shim-pack GIS series delivers high reproducibility, reduced method development time and compatibility with reversed-phase, normal-phase and HILIC modes, supporting QC, routine analyses and complex research separations.
Future Trends and Opportunities
Emerging developments may include novel stationary phase chemistries for enhanced selectivity, sub-2 µm and core-shell particles for faster UHPLC, AI-driven method optimization and expanded MS compatibility through low-bleed trap devices.
Conclusion
Adhering to recommended installation, operation and maintenance practices ensures consistent performance and extended service life of Shim-pack GIS columns, with proper system configuration and preventative measures vital for reliable HPLC outcomes.
Reference
Shimadzu Corporation. Shim-pack GIS Series Instruction Manual (ERAD-0001-9008A).
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
High Performance Packed Column for SFC
|Shimadzu|Manuals
ERAD-0001-9018A High Performance Packed Column for SFC Shim-pack UC Series INSTRUCTION MANUAL Introduction To maintain and maximize peak performance of Shim-pack UC series columns, and to ensure the long life and stability of columns, please read the following instructions…
Key words
shim, shimpack, packgroups, groupssil, sildiol, diolcholes, cholesdihydroxypropyl, dihydroxypropyloctadecylsilyl, octadecylsilylpye, pyepbr, pbrseries, seriescolumns, columnscolumn, columnhyp, hypgis
Shim-pack GIST/GISS Series INSTRUCTION MANUAL
|Shimadzu|Manuals
ERAD-0001-9007 High Performance Packed Column for HPLC Shim-pack GIST/GISS Series INSTRUCTION MANUAL Introduction Column Installation To maintain and maximize peak performance of Shim-pack GIST/GISS series columns, and to ensure the long life and stability of columns, please read…
Key words
gist, gistshim, shimpack, packgiss, gisscolumn, columnphenyl, phenylcolumns, columnsoperating, operatingseries, seriesgroups, groupspressure, pressuresolvent, solventeluent, eluentperformance, performanceprecautions
Shim-pack GWS Series INSTRUCTION MANUAL
|Shimadzu|Manuals
ERAD-0001-9009 High Performance Packed Column for HPLC Shim-pack GWS Series INSTRUCTION MANUAL Introduction To maintain and maximize peak performance of Shim-pack GWS series columns, and to ensure the long life and stability of columns, please read the following instructions…
Key words
gws, gwsshim, shimpack, packcolumn, columnseries, seriescolumns, columnsclogging, cloggingeluent, eluentprecautions, precautionsinstalling, installingperformance, performancephs, phsnoncompliance, noncompliancetubing, tubingconnection
High Performance Packed Column for HPLC - Scepter Series
|Shimadzu|Manuals
ERAD_0001-9043A High Performance Packed Column for HPLC Shim-pack Scepter Series INSTRUCTION MANUAL ■ Introduction The column should be connected with male nuts. Ensure that the To maintain and maximize peak performance of Shim-pack Scepter series columns, and to ensure the…
Key words
scepter, sceptershim, shimpack, packcolumn, columnprecautions, precautionspfpp, pfppphenyl, phenylpressure, pressureguard, guardeluent, eluentperformance, performancecolumns, columnsinstalling, installingvalve, valvepreparative