Agilent 280-DS Mechanical Qualification System
Brochures and specifications | 2012 | Agilent TechnologiesInstrumentation
The qualification of dissolution testing apparatus is essential in pharmaceutical quality control and regulatory compliance. Accurate mechanical qualification ensures reproducible dissolution results, minimizes batch failures, and supports patient safety by verifying that testing equipment consistently meets defined performance criteria.
This document introduces the Agilent 280-DS Mechanical Qualification System (MQS), designed to streamline and enhance the mechanical qualification of dissolution instruments. It aims to consolidate multiple manual gauges into two specialized modules controlled by dedicated software, reducing measurement time and variability while improving data integrity.
The Agilent 280-DS MQS consists of two modules:
These modules interface with the Agilent 280-DS Workstation Software, which guides users through the qualification sequence and stores data in a 21 CFR Part 11–compliant database.
Testing showed that the 280-DS MQS:
The integrated software offers preloaded regulatory methods, customizable protocols, user access controls, audit trails, data trending, and failure-investigation tools. Compatibility with most open-head dissolution systems is achieved through adjustable spacers and software-controlled spindle activation when used with Agilent models.
Implementing the 280-DS MQS delivers:
Cost analyses indicate annual savings exceeding 90% compared to traditional qualification methods when applied to multiple dissolution units.
Advances likely include integration with laboratory information management systems (LIMS), expanded remote monitoring capabilities, and predictive maintenance through trend analysis. Wider adoption may prompt the development of universal qualification standards leveraging digital data to drive continuous improvement in dissolution testing.
The Agilent 280-DS MQS represents a new standard in dissolution apparatus qualification by combining specialized hardware modules and robust software to simplify procedures, accelerate testing, and strengthen compliance. Its adoption can transform laboratory operations, offering significant time and cost savings while ensuring consistent, high-quality analytical results.
Dissolution
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies
Summary
Significance of Topic
The qualification of dissolution testing apparatus is essential in pharmaceutical quality control and regulatory compliance. Accurate mechanical qualification ensures reproducible dissolution results, minimizes batch failures, and supports patient safety by verifying that testing equipment consistently meets defined performance criteria.
Objectives and Overview of the Study
This document introduces the Agilent 280-DS Mechanical Qualification System (MQS), designed to streamline and enhance the mechanical qualification of dissolution instruments. It aims to consolidate multiple manual gauges into two specialized modules controlled by dedicated software, reducing measurement time and variability while improving data integrity.
Methodology and Used Instrumentation
The Agilent 280-DS MQS consists of two modules:
- Instrument Module (IM): Measures vessel plate level (X/Y axes) and vibration (X/Y/Z axes) using a tri-axial accelerometer; integrates a temperature probe attachment and USB interface.
- Vessel Module (VM): Measures spindle speed (RPM), basket and paddle wobble, shaft and basket verticality, vessel centering (upper and lower), and paddle/basket immersion height by expanding within the vessel wall without contacting the shaft.
These modules interface with the Agilent 280-DS Workstation Software, which guides users through the qualification sequence and stores data in a 21 CFR Part 11–compliant database.
Main Results and Discussion
Testing showed that the 280-DS MQS:
- Eliminates calibration of individual gauges by unifying measurements into a single system with traceable certification.
- Reduces total qualification time by up to 50%, enabling complete qualification in as little as 30 minutes per apparatus.
- Provides hands-free, non-contact measurement with real-time quantitative outputs for each critical parameter.
- Accurately captures resultant vibration magnitude and directional components, facilitating diagnosis of external and internal vibration sources.
The integrated software offers preloaded regulatory methods, customizable protocols, user access controls, audit trails, data trending, and failure-investigation tools. Compatibility with most open-head dissolution systems is achieved through adjustable spacers and software-controlled spindle activation when used with Agilent models.
Benefits and Practical Applications
Implementing the 280-DS MQS delivers:
- Greater laboratory throughput and flexibility to perform more frequent qualifications for improved equipment oversight.
- Enhanced data integrity through centralized digital records and electronic signatures.
- Lower operational costs by reducing labor hours, instrument downtime, and maintenance complexity.
- Streamlined compliance with global regulatory standards (USP, FDA/ASTM, ICH, FIP).
Cost analyses indicate annual savings exceeding 90% compared to traditional qualification methods when applied to multiple dissolution units.
Future Trends and Opportunities
Advances likely include integration with laboratory information management systems (LIMS), expanded remote monitoring capabilities, and predictive maintenance through trend analysis. Wider adoption may prompt the development of universal qualification standards leveraging digital data to drive continuous improvement in dissolution testing.
Conclusion
The Agilent 280-DS MQS represents a new standard in dissolution apparatus qualification by combining specialized hardware modules and robust software to simplify procedures, accelerate testing, and strengthen compliance. Its adoption can transform laboratory operations, offering significant time and cost savings while ensuring consistent, high-quality analytical results.
References
- No explicit literature references were provided in the original document.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 280-DS Mechanical Qualification System for Dissolution Apparatus 1 and 2
2016|Agilent Technologies|Technical notes
Agilent 280-DS Mechanical Qualification System for Dissolution Apparatus 1 and 2 A User-friendly System with Software Built for 21 CFR part 11 Compliance Technical Overview Authors Introduction Vinayak A.K and Dan Spisak The debate for the periodic qualification procedure of…
Key words
user, uservessel, vesselrecords, recordsqualification, qualificationbasket, basketmechanical, mechanicaldissolution, dissolutionsensors, sensorselectronic, electronicastm, astmfda, fdawobble, wobblereview, reviewcan, canfeatures
Proper Implementation of Enhanced Mechanical Calibration of Dissolution Apparatus 1 and 2
2012|Agilent Technologies|Technical notes
Proper Implementation of Enhanced Mechanical Calibration of Dissolution Apparatus 1 and 2 White Paper Authors Introduction Kenneth Boda and G. Bryan Crist Mechanical calibration of Dissolution Apparatus 1 and 2 has become an increasingly popular option for pharmaceutical companies since…
Key words
basket, basketdissolution, dissolutionmechanical, mechanicalvessel, vesselshould, shouldvibration, vibrationpaddle, paddleblade, bladeapparatus, apparatusshaft, shaftmeasurements, measurementsensure, ensurecalibration, calibrationchecked, checkedheight
Mechanical Qualification Guide
2012|Agilent Technologies|Posters
Mechanical Qualification Guide Vessel Measurement Dissolution Mechanical Qualification Specifications and Tolerances ICH Harmonized (USP, JP, EP) FDA DPA-LOP.002 ASTM E2503-07 Basket and paddle depth 25 ± 2 mm 25 ± 2 mm 25 ± 2 mm (or <8%) 23-27 mm…
Key words
basket, basketvessel, vesselwobble, wobblepaddle, paddleshaft, shaftverticality, verticalityrunout, runoutstainless, stainlesscentering, centeringsteel, steelmeasured, measureddissolution, dissolutiondamaged, damagedexamination, examinationsensors
Dissolution Workstation Software - Data Sheet
2018|Agilent Technologies|Brochures and specifications
Data Sheet Dissolution Workstation Software Agilent Dissolution Workstation Software provides complete, integrated control of all your dissolution systems from a single, networked interface Key benefits • Flexibility. Run up to four independent dissolution systems including the Agilent 708‑DS, USP Apparatus…
Key words
dissolution, dissolutionworkstation, workstationusb, usbsoftware, softwareaccess, accessvibration, vibrationsystem, systemyour, youraudit, auditsecurity, securityremote, remotetimepoints, timepointsrun, runprogresses, progressesport