Agilent 280-DS Mechanical Qualification System for Dissolution Apparatus 1 and 2
Technical notes | 2016 | Agilent TechnologiesInstrumentation
The mechanical qualification of dissolution apparatus is essential for guaranteeing accurate, reproducible dissolution testing, which underpins pharmaceutical quality control and regulatory compliance. Transitioning from chemical verification to enhanced mechanical qualification simplifies workflows, minimizes use of chemical standards, and maintains apparatus performance to meet USP, FDA, and ASTM requirements.
This technical overview describes the Agilent 280-DS Mechanical Qualification System (MQS) designed for USP dissolution apparatus 1 (baskets) and 2 (paddles). The system aims to provide rapid, precise physical measurements, ensure full 21 CFR Part 11 compliance, and guide operators through qualification workflows via user-friendly software.
The MQS comprises two modules:
The Agilent 280-DS MQS delivers:
Future developments may integrate qualification systems with laboratory information management platforms, expand remote monitoring, and leverage predictive analytics for maintenance optimization. Ongoing automation and digitalization will further strengthen compliance, reduce manual steps, and support real-time quality assurance in pharmaceutical operations.
The Agilent 280-DS MQS redefines dissolution apparatus qualification by combining precise optical sensing, intuitive software guidance, and comprehensive 21 CFR Part 11 compliance. It delivers faster, more accurate, and fully traceable measurements, streamlining laboratory workflows and reinforcing data integrity in line with global regulatory standards.
Software, Dissolution
IndustriesPharma & Biopharma
ManufacturerAgilent Technologies
Summary
Importance of the Topic
The mechanical qualification of dissolution apparatus is essential for guaranteeing accurate, reproducible dissolution testing, which underpins pharmaceutical quality control and regulatory compliance. Transitioning from chemical verification to enhanced mechanical qualification simplifies workflows, minimizes use of chemical standards, and maintains apparatus performance to meet USP, FDA, and ASTM requirements.
Objectives and Overview
This technical overview describes the Agilent 280-DS Mechanical Qualification System (MQS) designed for USP dissolution apparatus 1 (baskets) and 2 (paddles). The system aims to provide rapid, precise physical measurements, ensure full 21 CFR Part 11 compliance, and guide operators through qualification workflows via user-friendly software.
Methodology and Instrumentation
The MQS comprises two modules:
- Vessel Module: measures rotational speed, basket/shaft wobble, vessel and shaft centering, shaft verticality, and paddle or basket height.
- Instrument Module: monitors vessel plate level, vibration, and provides connections for temperature probes and the PC interface.
Used Instrumentation
- Agilent 280-DS Vessel Module
- Agilent 280-DS Instrument Module
- RS-232 communication cable
- Windows-based PC with Agilent 280-DS Workstation Software
Main Results and Discussion
The Agilent 280-DS MQS delivers:
- Reduction of qualification time to 15–30 minutes per apparatus versus manual gauges.
- Improved repeatability and elimination of user interpretation errors through real-time quantitative data.
- Secure electronic records, audit trails, and digital signatures conforming to 21 CFR Part 11.
- Trending analytics enabling early detection of performance drift and preventive maintenance.
Benefits and Practical Applications
- Compatibility across multiple dissolution apparatus brands, reducing the number of tools required.
- Data integrity through controlled user access, audit trails, and e-signatures in regulated environments.
- Customizable qualification methods aligned with pharmacopeial and internal standards.
- Enhanced lab productivity by consolidating mechanical checks into a single system.
Future Trends and Opportunities
Future developments may integrate qualification systems with laboratory information management platforms, expand remote monitoring, and leverage predictive analytics for maintenance optimization. Ongoing automation and digitalization will further strengthen compliance, reduce manual steps, and support real-time quality assurance in pharmaceutical operations.
Conclusion
The Agilent 280-DS MQS redefines dissolution apparatus qualification by combining precise optical sensing, intuitive software guidance, and comprehensive 21 CFR Part 11 compliance. It delivers faster, more accurate, and fully traceable measurements, streamlining laboratory workflows and reinforcing data integrity in line with global regulatory standards.
References
- Agilent Technologies Practical Solutions Newsletter, Vol. 11, Issue 1.
- LCGC Whitepaper 5991-6754EN: In-Depth Examination of the USP Performance Verification Test and Enhanced Mechanical Qualification.
- FIP Position Paper on Qualification of Paddle and Basket Dissolution Apparatus, AAPS.
- Agilent Whitepaper 5990-9866EN: Proper Implementation of Enhanced Mechanical Calibration of Dissolution Apparatus 1 and 2.
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
Agilent 280-DS Mechanical Qualification System
2012|Agilent Technologies|Brochures and specifications
Agilent 280-DS Mechanical Qualification System REDEFINE DISSOLUTION QUALIFICATION SIMPLIFY MECHANICAL QUALIFICATION Maximize Laboratory Efficiency and Data Integrity The Agilent 280-DS Mechanical Qualification System (MQS) will change your perspective on dissolution qualification. Using the 280-DS’s two devices – an Instrument Module…
Key words
qualification, qualificationdissolution, dissolutionvessel, vesselapparatus, apparatusvibration, vibrationpvt, pvtyour, youragilent, agilentperiodic, periodicall, allcompliance, complianceservices, servicesbasket, basketedition, editionusp
Mechanical Qualification Guide
2012|Agilent Technologies|Posters
Mechanical Qualification Guide Vessel Measurement Dissolution Mechanical Qualification Specifications and Tolerances ICH Harmonized (USP, JP, EP) FDA DPA-LOP.002 ASTM E2503-07 Basket and paddle depth 25 ± 2 mm 25 ± 2 mm 25 ± 2 mm (or <8%) 23-27 mm…
Key words
basket, basketvessel, vesselwobble, wobblepaddle, paddleshaft, shaftverticality, verticalityrunout, runoutstainless, stainlesscentering, centeringsteel, steelmeasured, measureddissolution, dissolutiondamaged, damagedexamination, examinationsensors
Proper Implementation of Enhanced Mechanical Calibration of Dissolution Apparatus 1 and 2
2012|Agilent Technologies|Technical notes
Proper Implementation of Enhanced Mechanical Calibration of Dissolution Apparatus 1 and 2 White Paper Authors Introduction Kenneth Boda and G. Bryan Crist Mechanical calibration of Dissolution Apparatus 1 and 2 has become an increasingly popular option for pharmaceutical companies since…
Key words
basket, basketdissolution, dissolutionmechanical, mechanicalvessel, vesselshould, shouldvibration, vibrationpaddle, paddleblade, bladeapparatus, apparatusshaft, shaftmeasurements, measurementsensure, ensurecalibration, calibrationchecked, checkedheight
AGILENT 708-DS DISSOLUTION APPARATUS TRAINING MANUAL
2010|Agilent Technologies|Manuals
Agilent 708-DS Dissolution Apparatus Training Manual AGILENT 708-DS DISSOLUTION APPARATUS TRAINING MANUAL Table of Contents 1.1. The Apparatus .......................................................................................................................... - 5 - 1.2. The Firmware ............................................................................................................................ - 6 - 1.3. Optional Configurations ........................................................................................................ - 6 - 2. INSTRUMENT SETUP .............................................................................…
Key words
revision, revisiontraining, trainingmanual, manualanywhere, anywherebox, boxpress, pressvessel, vesselspindle, spindleinside, insideshaft, shaftbath, bathmanifold, manifoldddm, ddmenter, enterscreen