It Isn’t Always the Column: Troubleshooting Your HPLC Separation
Presentations | 2023 | Agilent TechnologiesInstrumentation
High-performance liquid chromatography (HPLC) is a cornerstone of modern analytical chemistry. Consistent and reliable separations are essential in pharmaceutical, environmental, food, and industrial laboratories for quality control, research, and regulatory compliance. However, unexpected variations in pressure, peak shapes, retention times, and baseline stability can undermine data integrity, waste resources, and delay projects. Prompt identification of root causes beyond the column itself enhances uptime, extends column lifetime, and boosts confidence in analytical results.
This guide presents a structured approach to diagnosing HPLC separation issues. Key goals include:
The methodology employs systematic flow-path isolation: disconnecting capillaries, performing pressure and pump diagnostics, backflushing clogged parts, and verifying instrument performance with standard test procedures. Preventive practices focus on filtration, degassing, and scheduled component replacements.
Troubleshooting is organized by symptom:
Applying this troubleshooting framework minimizes downtime, extends consumable life, and standardizes service procedures. It supports robust method development and routine QC across diverse HPLC applications—UHPLC, 2D-LC, bio-inert analyses, and routine pharmaceutical assays.
Advances in real-time diagnostics, automated system health monitoring, and smart consumables will further enhance HPLC reliability. Development of novel stationary phases and frit technologies aims to reduce blockages, while bio-inert flow paths and integrated software tools promise seamless maintenance and faster issue resolution.
A holistic troubleshooting strategy that examines the entire flow path, instrumentation, and data system—not just the column—ensures consistent HPLC performance. Combining diagnostic tests with preventive filtration and maintenance delivers reproducible separations and high data integrity.
HPLC
IndustriesManufacturerAgilent Technologies
Summary
Importance of the Topic
High-performance liquid chromatography (HPLC) is a cornerstone of modern analytical chemistry. Consistent and reliable separations are essential in pharmaceutical, environmental, food, and industrial laboratories for quality control, research, and regulatory compliance. However, unexpected variations in pressure, peak shapes, retention times, and baseline stability can undermine data integrity, waste resources, and delay projects. Prompt identification of root causes beyond the column itself enhances uptime, extends column lifetime, and boosts confidence in analytical results.
Objectives and Study Overview
This guide presents a structured approach to diagnosing HPLC separation issues. Key goals include:
- Defining core questions to track when and how the system last performed correctly.
- Mapping potential failure points along the HPLC flow path.
- Outlining causes, immediate actions, and preventive measures for common symptoms.
Methodology and Instrumentation Used
The methodology employs systematic flow-path isolation: disconnecting capillaries, performing pressure and pump diagnostics, backflushing clogged parts, and verifying instrument performance with standard test procedures. Preventive practices focus on filtration, degassing, and scheduled component replacements.
Used Instrumentation
- Agilent InfinityLab UHPLC/HPLC system: pump with degasser, autosampler, and column compartment thermostat
- Diode-array (DAD) or UV detector with adjustable flow cell volume and data acquisition rate
- InfinityLab Quick Connect and Quick Turn high-pressure fittings
- Inline frits, syringe and solvent inlet filters, and guard columns
- Agilent Lab Advisor diagnostic software
Main Results and Discussion
Troubleshooting is organized by symptom:
- System Pressure: Blockages from particulates or microbial growth increase backpressure; leaks or pump defects cause low or fluctuating pressure.
- Peak Shape: Tailing, fronting, splitting, and broadening often arise from column degradation, incorrect injection solvent strength, extracolumn dispersion, or improper data rates.
- Retention Time Shifts: Variations in flow rate, gradient mixing, mobile-phase volatility, temperature control, or column contamination drive shifting retention times.
- Baseline Stability: Noise and drift can result from dissolved gases, lamp aging, solvent impurities, or pressure instabilities.
Benefits and Practical Applications of the Method
Applying this troubleshooting framework minimizes downtime, extends consumable life, and standardizes service procedures. It supports robust method development and routine QC across diverse HPLC applications—UHPLC, 2D-LC, bio-inert analyses, and routine pharmaceutical assays.
Future Trends and Potential Applications
Advances in real-time diagnostics, automated system health monitoring, and smart consumables will further enhance HPLC reliability. Development of novel stationary phases and frit technologies aims to reduce blockages, while bio-inert flow paths and integrated software tools promise seamless maintenance and faster issue resolution.
Conclusion
A holistic troubleshooting strategy that examines the entire flow path, instrumentation, and data system—not just the column—ensures consistent HPLC performance. Combining diagnostic tests with preventive filtration and maintenance delivers reproducible separations and high data integrity.
References
- Agilent InfinityLab Column User Guides
- LC Troubleshooting Guide 5994-0709EN
- Agilent Lab Advisor Diagnostic Software Documentation
- InfinityLab Quick Connect Fittings Brochure 5991-5164EN
Content was automatically generated from an orignal PDF document using AI and may contain inaccuracies.
Similar PDF
My Chromatography Has Changed: Steps for Effective Troubleshooting
2024|Agilent Technologies|Presentations
My Chromatography Has Changed: Steps for Effective Troubleshooting Jean Lane Applications Engineer LC Columns and Consumables Technical Support June 18, 2024 1 6/18/2024 My Chromatography has Changed: Steps for Effective Troubleshooting DE13277529 Common Symptoms and Problems • Increased pressure •…
Key words
mobile, mobilephase, phasecolumn, columnpressure, pressurefilter, filtercheck, checkaction, actionfitting, fittingpeak, peakquick, quickyour, yourconnections, connectionsinfinitylab, infinitylabuse, usetailing
From HPLC Instrument to Column - Tracking Down the HPLC Problem
2022|Agilent Technologies|Presentations
From Instrument to Column Tracking Down the Problem Melissa Goodlad Applications Engineer Columns and Supplies Technical Support 1 5/27/2022 From Instrument to Column: Tracking Down the Problem DE27255094 Troubleshooting Topics System pressure • Increased pressure • Low pressure Peak shape…
Key words
lamp, lampmobile, mobileaction, actioncheck, checkpressure, pressuresolvent, solventseat, seatneedle, needletests, testsphase, phasediode, diodefitting, fittingchanges, changesparts, partsreplace
Why Did That Happen?
2021|Agilent Technologies|Presentations
“"Why Did That Happen?"” Golnar Javadi Applications Engineer LC Columns and Consumables Technical Support March 31, 2021 "Why Did That Happen?" Common chromatography problems Changes in System Pressure • High pressure • Low pressure • Pressure fluctuations 1 Changes in…
Key words
happen, happenwhy, whydid, didporoshell, poroshellfilter, filteryes, yeselut, elutinfinitylab, infinitylabpressure, pressurechanges, changessolvent, solventspe, spephase, phaseinline, inlinecaptiva
Surviving Chromatography - Part 2: Corrective Action
2018|Agilent Technologies|Presentations
Surviving Chromatography Part 2: Corrective Action Jean Lane Applications Engineer LC Columns & Consumables Technical Support October 11, 2018 1 October 10, 2018 Agilent restricted “My Chromatography is Not Where it Should be” – Points for Discussion for chromatography that…
Key words
column, columnplugged, pluggedpressure, pressurefrit, fritmobile, mobilereplace, replacephase, phaseshape, shapeproblems, problemscauses, causessolvent, solventpeak, peakpeaks, peaksdetach, detachecv